AXLINK100 892.202988
AXLINK100 892.202988
AXLINK100 892.202988
ndustrS900是用于过程控制站的分布式I/0,它们通过Prof ibusDP现场总线与其所属的控制器
通信,既可以安装在控制室,也可以安装在现场以尽量接近现场变送器和执行器,从而 节省电缆并
减少安装费用。
S800 1/0及s900 I/0 具有以下优点:
●灵活性:对安装数量没有限制,可小数量安装,也可大量安装,可以安装在室内,也可安装在室
外,可以安装在墙上,也可安装在机柜中。
●模块化:可一步一步扩展,不会因自身限制而影响系统扩展。
●经济性:节省硬件,电缆,从而节省安装及维护费用.
●可靠性:因其自诊断及冗余等特性,可平滑的实现自动切换。
S800/S900型1/0 采用模块化设计,DIN 标准导轨式安装,由于对空间以及环境要求不苛刻,
S800/S900型I/0尤其适用于安装在分散的场合,并且对处理信号几乎没有要求,从而现场仪表和设
备信号可以直接接线到S800/S900 I/0 站。
其它特性: .
●所有模件具备故障自诊断功能并具有LED故障显示
●丰富的I/0模件类型,模拟量I/0精度≤0.1I%
●支持电源冗余
●所有I/0均可设定安全值
●具有短路保护功能
●所有模件 均可带电插拔,并自动识别
●支持冗余 现场总线
●支持HART协议通讯(S900所有I/0模件及部分及部分S800I/O卡件)
●具备本质安全特性(S900所有I/0模件及部分S800模件,BBx ia II C)
●可直接安装在危险区1区(仅S900)
S800 I/0 及S900 I/0采用Profibus DP通信协议。
S800/S900型I/0具有多种模拟及数字输入输出模件,以及热电阻和热电偶模件。所有I/0 模件
均通过了多种恶劣环境及应用领城的测试,证实了它在极其恶劣场合应用下的寿命及可靠性。
5
to the basic ones specified in the IEC 61131 3 standard
In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control
The scheme can be realized by the combination of these function blocks.
The function blocks provided by the system mainly include the following categories:
o
Analog processing
o
digital processing
loop regulation
Logical sequence control
c
logic operation
Monitoring function
Collection function.
c
arithmetic operations
c
TCP/IP protocol communication interface
Modbus protocol communication interface
1EC870-5 protocol communication interface (Telecontrol)
4.2 Field Controller PS
Industrial” field controller PS is a special process control station, which is embedded with field bus communication interface for users to use
Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different),
Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and play
(Plug & Play), and can be plugged and unplugged.
The field controller PS has the following characteristics:
o
Flexible: supports all international standard open fieldbuses and can be mixed
Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd)
Allowable operating ambient temperature…60 C, with automatic temperature monitoring
o
EMC (Electromagnetic Compatibility) according to EN50082
mouth
Certifications: CE, NAMUR, CSA, CSA-NRT
In the investment of modern automation system, due to the hardware equipment department
It only takes up less cost in the whole system, then write engineering applications
The cost of software becomes increasingly important. Generally speaking, a self
The engineering application software cost of the automation project accounts for about the entire project.
About 50%, it is not difficult to see that the migration of co
Glossary
Process station:
This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant
configuration and non-redundant configuration.
AC800F :
This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2
AC800F controller.
Rack mounted process station:
This term is used to describe a rack-mounted type of process station. A redundant process station contains 2 rack-mounted CPUs.
This term is used to describe a single, non-redundant process station.
Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software
mouth
Access to all information from the field including equipment management information
Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems
Module identification with production operating parameters
c
complete self-diagnosis
Compact and robust design
Front Panel Wiring
DIN rail (U-shaped) installation well can be directly wall mounted, simple and convenient
o