5SHY35L4520 5SXE10-0181 AC10272001R0101
5SHY35L4520 5SXE10-0181 AC10272001R0101
5SHY35L4520 5SXE10-0181 AC10272001R0101
于现场设备、过程控制站和操作员站,整个控制系统采用了一个统一的全局数据库,从而降低
了建立数据通信及交互访问的成本和时间投资.
并保证整个系统范围内数据的一致性。
●提供系统全局范围的用户应用程序统一检查,覆
盖过程控制站、操作员站到智能的现场设备,包
括对用户程序的完整性和一致性检测。
●编程语言严格遵守IEC61131-3的国际标准,并具
有高性能的图形编辑功能:
-功能块图(FBD)
-梯形图(LD)
-指令表(IL)
-顺控图(SFC)
. 结构文本(ST)
●宽泛的功能块库,用户自定义的功能块也可以添
加到其中,宏库和图形符号可以为用户自定义功
能块建立图形和操作面板。
●可以通过GSD文件导入的方式来集成任何标准
PROFIBUS-DP和PA设备,并通过用户自定义对
话框形式来设计对这些设备组态配置的窗口。
●可以通过FDT/DTM技术来集成PROFIBUS现场总
线设备
of the system control station is all metal enclosure, which can withstand the most
stem communication
Industrial ial “the system uses the international standard industrial bus. The field controller supports PROFIBUS, FF, MODBUS, can and other countries
International standard fieldbus, PROFIBUS is the most widely used open fieldbus international standard in the world, which is divided into FMS, DP and pa
Level III, DP communication rate can be up to 12MB. PROFIBUS is used to connect distributed i/0 stations, field bus instruments and other intelligent devices.
The communication among process station, operator station and engineer station is realized through the system bus diginets (Industrial Ethernet). user
Different transmission media (RJ45 twisted pair, thin cable, thick cable or optical fiber cable and mixed media) and network topology can be selected for the system bus
Due to the adoption of tcp/ip protocol, the system can also realize ultra long distance communication with the help of public telephone network (dial-up mode) or satellite.
PLC and other subsystems communicate with industrial “system through Modbus protocol interface. The system also supports iec870-5 over control coordination
Discussion.
The flash EPROM inside PS provides more than 220 function modules (control algorithm subroutines), in addition to the base specified in IEC 61131 3 standard
In addition to this content, many powerful and strictly tested function blocks from practical engineering applications are also expanded. Any complex control
All schemes can be realized by the combination of these function blocks.
The function blocks provided by the system mainly fall into the following categories:
o
Analog quantity processing
o
Digital quantity processing
Loop adjustment
Logical sequence control
c
Logical operation
Monitoring function
Acquisition function
c
Arithmetic operation
c
Tcp/ip protocol communication interface
Modbus protocol communication in
(plug & play) and can be plugged in and out with power.
The field controller PS has the following features:
o
Flexible: it supports all international standard open fieldbus and can be mixed
4 high-speed fieldbuses can be connected at the same time (max. 12 MBD)
Simple project: only use the same tool CBF (control build f) software for configuration, debugging and diagnosis
mouth
Access to all information from the site, including equipment management information
Global database of Fieldbus equipment, control level and HMI (human-machine interface)
Module identification with production operating parameters
c
Complete self diagnosis
Compact and rugged design
Front panel wiring
DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient
o
Allowable operating ambient temperature 60 C, automatic temperature monitoring
o
EMC (electromagnetic compatibility) conforms to en50082 standard
mouth
Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd
Installation area: Class 1 div 2
The PS supports the following types of fieldbus standards:
Profibus DP,up to 12 MBd
Modbus RTU,1200 to 38. 4KBd
Industrial” CAN I/0 Bus
o
Open CAN -Bus,up to 1 MBd
o
Foundation Fieldbus H1
up to 31. 25KBd
Foundation Fieldbus H2 (fast Ethernet)
HART
The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS.
Industrial “field control explosion (AC800F) consists of the following components:
Basic unit pm802f
Power supply sa801f/sd802f
o
Ethernet network card ei801f/ei802f/ei803f
o
Fieldbus interface card fi810f/fi820f/fi830f
Various accessories
The main components of the field controller PS are described below.
Basic unit pm802f
The basic unit pm802f is composed of a metal rack and a CPU motherboard. It period
HART
The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS.
Industrial “field control explosion (AC800F) consists of the following components:
Basic unit pm802f
Power supply sa801f/sd802f
o
Ethernet network card ei801f/ei802f/ei803f
o
terface
1ec870-5 protocol communication interface (telecontrol)
4.2 field controller PS
Industrial ial “field controller PS is a special process control station, which is embedded with a fieldbus communication interface for users to use
Fieldbus technology provides a very flexible choice. Each PS is allowed to insert 4 fieldbus interface cards (card types can be different),
Each card is connected to a fieldbus to collect process data and diagnostic information from the bus. The interface card is easy to replace and plug and play